*Unit may not be exactely as shown |
Operating Paramters | |
Permeate Flow: | 7.50 usgpm @ 25 deg C |
|
Concentrate Flow: | 2.50 usgpm @ 25 deg C | |
Recycle Flow: | 3.00 usgpm @ 25 deg C | |
Feed Flow | 10.00 usgpm @ 25 deg C | |
Operating Pressure: | 200 PSI | |
Recovery: | 75% | |
Rejection | 98% average | |
Dimensions | ||
Height: | 60" | |
Width: | 28" | |
Depth: | 28" | |
Weight: | 300 lbs |
Features:
- Low Energy Membrane reduces horse power requirements and operating costs.
- 5 Micron Pre Filter.
- Automatic Inlet Shut Off Solenoid Valve.
- Permeate and Concentrate Flow Meters
- Pre Filter, Post Filter and Membrane Pressure Guages
- Waste Water Recycle Kit for maximum water savings.
- Low Pressure Shut Off for maximum pump protection
- Thermal Motor Protection
- 20" Cartridge with 5 Micron Filter
Booster Pump:
- Multi Stage Booster Pump
- Optional 3 Phase Power
Materials of Construction:
- Frame: Epoxy Coated Carbon Steel
- Membrane Vessel: PVC
- Inlet Plumbing: Sch 80 PVC and Brass
- High Pressure, Permeate and Concentrate Plumbing: High Density FDA Approved Polyethylene tubing with compression brass fittings
- Control Enclosure: R & D Specialties - Series 100
Options:
- High Quality Recycle Flow Meter
- Permeate Flush
- Feed Water Flush
- Pre-Treat Lock Out
- Digital TDS Meter
- Stainless Steel Pump
- Stainless Steel Pre Filter
- Stainless Steel Membrane Housing
- High Rejection Membranes (99.6%)
Membranes:
- Membrane Element Model: Osmonics AK4040FF
- Number of Membranes: 5
- Membrane Array: 2-1-1-1
- Membrane Vessel: PVC
- Number of Membrane Vessels: 5
Installation Requirements
- Inlet: 1" - FPT
- Permeate: 3/4"
- Concentrate: 3/4"
- Inlet Pressure: 30 psi minimum
- Motor Power: Optional